IMPORTANT TECHNICAL BULLETIN FOR COMPAKTOR USERS
If you are running z/OS 1.8 or higher and you are using new PDSE features PDSE_BUFFER_BEYOND_CLOSE(YES) and/or PDSE1_BUFFER_BEYOND_CLOSE(YES), you will need to apply the following ZAP as soon as possible.
COMPAKTOR V5.4 L61 shipments on September 6th, 2007 and later will automatically have this zap P-54.5600 included. If you are running a version of COMPAKTOR lower than V5.4 L55, you will need to upgrade.
***** ZAP-ID# : P-54.5600
* DATE : 07.247
* SYMPTOMS : ABEND S0F4, SVC DUMP WITH
* TITLE=COMPID=DF115,CSECT=IGWBIEX1+0B0E. AFTER
* MOVING PDSE FILE ON Z/OS 1.8 WITH BUFFER BEYOND
* CLOSE FEATURE ENABLED.
* PROBLEM : Z/OS 1.8 HAS THE NEW OPTIONS
* PDSE_BUFFER_BEYOND_CLOSE(YES) AND
* PDSE1_BUFFER_BEYOND_CLOSE(YES) TO KEEP PDSE
* DIRECTORY AND MEMBER DATA IN MEMORY AFTER A PDSE
* IS CLOSED. IF CPK MOVES THESE DATA SETS, SYSTEM
* ABENDS AND OTHER ERRORS OCCUR.
* SOLUTION : ISSUE IGWNOTIF TO CLEAR IN-CORE BUFFERS.
* MODULE(S) : FDRRESTR
*-
NAME FDRRESTR FDRRESTR
IDRDATA P545600
VER 07AE 9180,D64B,4780,C7FA,9102,905A,4780,C7FA
VER 07BE 9108,9056,4780,C7FA
VER 1CD0 BCD0,BCD2
REP 07AE 9102,905A,4780,C7FA,9108,9056,4780,C7FA
REP 07BE 47F0,BCD0,0101,0100
REP 1CD0 9142,D647,4780,C7C6,9102,9056,4710,C7C6
REP 1CE0 58E0,0010,58E0,E4C0,D503,E010,C7C2,4740
REP 1CF0 C7C6,58E0,E02C,BFEF,E0B4,4780,C7C6,4110
REP 1D00 003C,0A6B,4110,D958,D70B,1000,1000,9202
REP 1D10 1001,D205,1002,D1F0,1FFF,BFF3,9000,4CF0
REP 1D20 D40C,4AF0,9002,40F0,1008,D200,100A,9004
REP 1D30 18FE,0CEF,4110,0024,0A6B,47F0,C7C6
CHECKSUM FB66DC02
*
***** END OF MODIFICATION
NOTE:
You can display the current PDSE options with the operator command D SMS,OPTIONS.
If your options are set as follows, you do not have any exposure to this problem but we recommend that
you still apply the zap.
PDSE_BUFFER_BEYOND_CLOSE = NO
PDSE1_BUFFER_BEYOND_CLOSE = NO
If either of these options is set to YES, and you run FASTCPK on volumes containing PDSEs,
then you must upgrade COMPAKTOR or apply ZAP P-54.5600 before the next FASTCPK run. If there will be a delay,
then you can change the options by specifying:
PDSE_BUFFER_BEYOND_CLOSE(NO)
PDSE1_BUFFER_BEYOND_CLOSE(NO)
in PARMLIB member IGDSMSxx, and re-IPLing.
This fix can be downloaded from the Innovation FTP site at
http://www.innovationdp.fdr.com/ftp/ftp.cfm
from file
/download/FDR_V54/P545600.txt
If you have not already registered for FTP access, click on the "Register for FTP Site Access" link.
If you are already registered, enter your access code (use capitals for
any letters in your access code) and click on the "FTP Login" link.
To upgrade, please click on this link: http://www.innovationdp.fdr.com/upgrade/exform.cfm
|